 1. 

A porcelain lampholder with a pull-chain ____ permitted to serve as the lighting outlet required by NEC® 210.70(A)(3).
a.
is
b.
is not
 

 2. 

A detached garage with electric power is required to have ____.
a.
at least one receptacle
b.
at least two receptacles
c.
at least one receptacle in addition to any provided for a permanently installed appliance such as a freezer
d.
at least one receptacle outlet and one lighting outlet
 

 3. 

GFCI protection is required for all accessible receptacles installed in a garage or storage building. Which of the following is not considered accessible?
a.
a receptacle provided for a permanently installed appliance such as a freezer
b.
a ceiling-mounted receptacle for an electric garage door opener
c.
a receptacle intended for use with portable electric power tools
d.
both a and b
 

 4. 

To provide shock protection, low-voltage wiring systems are required by Article 411 to be ____.
a.
double-insulated
b.
grounded
c.
supplied though isolating transformers
d.
all of these
 

 5. 

Overhead conductors ____ permitted to be supported by trees.
a.
are
b.
are not
 

 6. 

Outdoor lighting fixtures and associated equipment ____ permitted to be supported by trees.
a.
are
b.
are not
 

 7. 

Type UF "underground feeder" cable ____ permitted to be used to supply service entrances.
a.
is
b.
is not
 

 8. 

Which of the following types of cable are permitted to be used for direct-burial applications?
a.
Type NMB
b.
Type UF
c.
Type USE
d.
both b and c
 

 9. 

Metallic conduit buried underground must be protected against ____.
a.
backhoes
b.
corrosion
c.
galvanic action
d.
all of these
 

 10. 

The minimum depth for a 120-volt, 15-ampere, GFCI-protected circuit to an outdoor pole light run under a paved driveway is ____.
a.
6 inches
b.
12 inches
c.
18 inches
d.
24 inches
 

 11. 

When outdoor receptacles are installed where a cord will be plugged in permanently, such as for decorative lighting, the box cover ____ maintain weatherproof integrity when the cord is plugged in.
a.
must
b.
need not
 

 12. 

The type of cable most often used for television signal distribution in new residences is ____.
a.
300-ohm twin-lead
b.
150-ohm unshielded twisted-pair
c.
75-ohm coaxial
d.
Type FLP
 

 13. 

When 120-volt receptacles and TV outlets are mounted in double-gang boxes, ____ is required in the box to isolate the TV conductors from the power wiring.
a.
a metal EMI shield
b.
a barrier
c.
double-grounding
d.
double-insulation
 

 14. 

The article that covers TV wiring installations in residences is Article ____.
a.
725
b.
810
c.
820
d.
none of these
 

 15. 

Which of the following rules apply to coaxial cable installations under Article 820?
a.
The outer shield of the coaxial cable must be grounded close to its point of entry into the building.
b.
Coaxial cables shall not be installed in the same raceways or enclosures as electric light and power conductors.
c.
Coaxial cables are not permitted to be fastened to raceways that contain electric light and power conductors.
d.
all of these
 

 16. 

The term gigahertz means ____.
a.
million cycles per second
b.
million bytes per second
c.
billion cycles per second
d.
billion bytes per second
 

 17. 

Residential telephone conductor installations must be made in accordance with the requirements of ____.
a.
Article 800
b.
Article 810
c.
Article 820
d.
none of these
 

 18. 

Transformers and low-voltage wiring for doorbells are classified as ____ circuits under Article 725.
a.
Class 1
b.
Class 2
c.
Class 3
d.
Power-limited
 

 19. 

It ____ permitted to install Class 2 wiring in the same raceway or enclosure as electric light and power wiring.
a.
is
b.
is not
 

 20. 

Signaling circuit is defined in ____.
a.
Article 100
b.
NEC® 725.1
c.
NEC® 725.10(C)
d.
NEC® 800.3(B)(2)
 

 21. 

According the layout of the garage, attic light and exterior ,light complete the wiring diagram. identify each conductor with a letter or use a color pencil
mc021-1.jpg
a.
mc021-2.jpg
b.
mc021-3.jpg
 



 
         Start Over