WELCOME TO MR.P WEBSITE
  • Home
    • PLC FIDDLE PROJECTS
  • Personal Info
  • MY MEDIA FILES
  • FTC
    • FTC SM Projects Folder
    • PLC SIMULATOR
    • FTC ELE2101 NCCERL3M3 Term4C
    • FTC ELE2101 NCCERL3M4 Term4C
    • HVA1400 Midterm
    • NCCER Electrical HTML Tests >
      • NCCER Elect L04M02
      • L04M10 Elect Motors Maintenance
      • L02M08 Conductor Terminations and Splices
      • L02M09 Grounding and Bonding
    • FTC Student contact list
    • Motor Calculation
    • CHILLERS MAG BEARINGS
    • My youtube channel
    • ATTENDANCE
    • EPA 608 TPC Study guide >
      • ESCO Practice Manual 9ed 2018
      • EPA 608 Core Batch 1
    • HVACR House Load Calculation
    • CLICK PLC User Manual
    • NCCER useful links
    • PLC3000 07/29/19 ATTN sheet
    • Simulation links
    • Youtube plyalist for HVACR training
    • Microsoft One Note tutorial
    • Heat pump sequencer Heat sequencer
    • Brazing Settings
    • CH 81
    • FTC HVA 1171 Comm Ref and A/C
    • HVACR Duct Calculation
    • HVACR simulator >
      • CENGAGE DELMAR HVAC Sim
    • Compressors
    • Brazing Lab
    • SURVEY
    • HVA1220 Mech Instrut Lab >
      • TESTS
      • LABS
    • FTC HVA 1170 Domestic A/C Refrigeration >
      • Quizzes
      • FINAL EXAM
    • ELE2053 Dig Electronics >
      • Labs
      • Tests
      • PPTs
      • Refrigerants CHART
      • Homeworks
      • MITSUBISHI MR. SLIM
  • CBT College
    • Affidavit of Ackownoledge
    • EET1033 Fundamentals DC/AC >
      • SYL
      • Homework
    • Cutler Bay Campus Calendar
    • FES1155 Fire Alarm Sys >
      • Affidavit
      • HOMEWORKS
      • Syllabus
      • Study Guide
      • FASA Book
      • FX-64 Technical Manual
      • Programming Tutorial video linkew pageP
      • Tests
    • BCT1630 Residential Wiring >
      • Syllabus
      • Affidavit
      • Grade Book
      • HOMEWORKS
    • EEV1230 Low Voltage Systems >
      • AFFIDAVIT
      • ATTENDANCE
      • LABS
      • GRADEBOOK
      • HOMEWORKS
      • LABS
      • SYLLABUS
      • EEV1230 Tests
      • EEV1230 Final Study guide
      • EEV1230 Low Voltage Final Exam
      • DSC PC1616 PDF Manual
    • EET1051 EMC >
      • HOMEWORKS
      • SYLLABUS
      • EET1051 Study Guide
    • NDS LOW VOLTAGE
  • Blog
  • JOURNEYMAN PREP
  • NDS EEV1230 LOW VOLTAGE
  • ATTENDANCE
  • EEV1230 ATT
  • 608
  • BLENDER TUTORIAL

FTC ELE2101 NCCER L3M3 Term04C
 
Name:     ID: 
 
Email: 

FTC ELE2101 NCCER L3M3 Term04C

Multiple Choice
Identify the choice that best completes the statement or answers the question.
 

 1. 

The classification of an area as being hazardous with regard to the installation of lighting fixtures is the responsibility of the insurance company, authority having jurisdiction, or
      .
a.
owner
c.
electrician
b.
NFPA
d.
utility company
 

 2. 

Corridor lighting levels in the public areas of a building should have at least       .
a.
the same illuminance level as the adjacent areas
b.
20% of the illuminance level of the adjacent areas
c.
50% of the illuminance level of the adjacent areas
d.
75% of the illuminance level of the adjacent areas
 

 3. 

Lighting that uses fixtures above the visual task area that also contributes to the lighting in the local area is classified as       .
a.
local lighting
c.
localized general lighting
b.
task lighting
d.
accent lighting
 

 4. 

Task lighting is used to       .
a.
emphasize art or décor
c.
focus illumination on a specific surface
b.
illuminate a vertical surface
d.
provide minimum exit lighting
 

 5. 

Lighting fixtures that distribute 60% to 90% of their emitted light downward but also distribute 10% to 40% upward to illuminate the ceiling are classified as       .
a.
direct lighting fixtures
c.
semi-direct lighting fixtures
b.
diffused lighting fixtures
d.
direct-indirect lighting fixtures
 

 6. 

Lighting fixtures installed in houses and apartments are classified as being used in       .
a.
commercial service
c.
street service
b.
security service
d.
residential service
 

 7. 

Which of the following types of lighting fixtures is most likely to be used to provide general illumination in patient observation areas in a health care facility?
a.
Fluorescent
c.
Halogen
b.
Incandescent
d.
HID
 

 8. 

Which of the following is used in HID dimming circuits to detect movement as people enter and to bring the aisle lighting to full luminance?
a.
SL
c.
SLIP
b.
SLD
d.
SLOD
 

 9. 

Task area fluorescent fixtures are generally two-, three-, or four-lamp fixtures made in lengths of       .
a.
1' and 4'
c.
4' and 8'
b.
3' and 6'
d.
5' and 9'
 

 10. 

Which of the following is a common name for a lighting trolley plug-in device?
a.
Wall pack
c.
Twistout
b.
Cobra head
d.
Bay
 

 11. 

Which of the following is the unit used to measure the illuminance or amount of total light per unit area that falls on a surface?
a.
Footcandle
c.
Lumen
b.
Candlepower
d.
Watt
 

 12. 

Lighting that provides the minimum light levels needed to assist people when exiting a building is classified as       .
a.
general lighting
c.
wall-wash lighting
b.
egress lighting
d.
accent lighting
 

 13. 

When mounted above eye level, which of the following are normally equipped with some bottom shielding, such as a louver or diffuser?
a.
HID fixtures
c.
Bollard fixtures
b.
Floodlights
d.
Downlights
 

 14. 

The basic measure of the amount of light produced by a light source is called the       .
a.
incandescence
c.
footcandle
b.
candlepower
d.
lumen
 

 15. 

Magnetic dimming ballasts allow fluorescent lamps to be safely dimmed to what percentage of their full light output?
a.
10%
c.
30%
b.
20%
d.
40%
 



 
         Start Over
Powered by Create your own unique website with customizable templates.
  • Home
    • PLC FIDDLE PROJECTS
  • Personal Info
  • MY MEDIA FILES
  • FTC
    • FTC SM Projects Folder
    • PLC SIMULATOR
    • FTC ELE2101 NCCERL3M3 Term4C
    • FTC ELE2101 NCCERL3M4 Term4C
    • HVA1400 Midterm
    • NCCER Electrical HTML Tests >
      • NCCER Elect L04M02
      • L04M10 Elect Motors Maintenance
      • L02M08 Conductor Terminations and Splices
      • L02M09 Grounding and Bonding
    • FTC Student contact list
    • Motor Calculation
    • CHILLERS MAG BEARINGS
    • My youtube channel
    • ATTENDANCE
    • EPA 608 TPC Study guide >
      • ESCO Practice Manual 9ed 2018
      • EPA 608 Core Batch 1
    • HVACR House Load Calculation
    • CLICK PLC User Manual
    • NCCER useful links
    • PLC3000 07/29/19 ATTN sheet
    • Simulation links
    • Youtube plyalist for HVACR training
    • Microsoft One Note tutorial
    • Heat pump sequencer Heat sequencer
    • Brazing Settings
    • CH 81
    • FTC HVA 1171 Comm Ref and A/C
    • HVACR Duct Calculation
    • HVACR simulator >
      • CENGAGE DELMAR HVAC Sim
    • Compressors
    • Brazing Lab
    • SURVEY
    • HVA1220 Mech Instrut Lab >
      • TESTS
      • LABS
    • FTC HVA 1170 Domestic A/C Refrigeration >
      • Quizzes
      • FINAL EXAM
    • ELE2053 Dig Electronics >
      • Labs
      • Tests
      • PPTs
      • Refrigerants CHART
      • Homeworks
      • MITSUBISHI MR. SLIM
  • CBT College
    • Affidavit of Ackownoledge
    • EET1033 Fundamentals DC/AC >
      • SYL
      • Homework
    • Cutler Bay Campus Calendar
    • FES1155 Fire Alarm Sys >
      • Affidavit
      • HOMEWORKS
      • Syllabus
      • Study Guide
      • FASA Book
      • FX-64 Technical Manual
      • Programming Tutorial video linkew pageP
      • Tests
    • BCT1630 Residential Wiring >
      • Syllabus
      • Affidavit
      • Grade Book
      • HOMEWORKS
    • EEV1230 Low Voltage Systems >
      • AFFIDAVIT
      • ATTENDANCE
      • LABS
      • GRADEBOOK
      • HOMEWORKS
      • LABS
      • SYLLABUS
      • EEV1230 Tests
      • EEV1230 Final Study guide
      • EEV1230 Low Voltage Final Exam
      • DSC PC1616 PDF Manual
    • EET1051 EMC >
      • HOMEWORKS
      • SYLLABUS
      • EET1051 Study Guide
    • NDS LOW VOLTAGE
  • Blog
  • JOURNEYMAN PREP
  • NDS EEV1230 LOW VOLTAGE
  • ATTENDANCE
  • EEV1230 ATT
  • 608
  • BLENDER TUTORIAL