WELCOME TO MR.P WEBSITE
Home
PLC FIDDLE PROJECTS
Personal Info
MY MEDIA FILES
FTC
FTC SM Projects Folder
PLC SIMULATOR
FTC ELE2101 NCCERL3M3 Term4C
FTC ELE2101 NCCERL3M4 Term4C
HVA1400 Midterm
NCCER Electrical HTML Tests
>
NCCER Elect L04M02
L04M10 Elect Motors Maintenance
L02M08 Conductor Terminations and Splices
L02M09 Grounding and Bonding
FTC Student contact list
Motor Calculation
CHILLERS MAG BEARINGS
My youtube channel
ATTENDANCE
EPA 608 TPC Study guide
>
ESCO Practice Manual 9ed 2018
EPA 608 Core Batch 1
HVACR House Load Calculation
CLICK PLC User Manual
NCCER useful links
PLC3000 07/29/19 ATTN sheet
Simulation links
Youtube plyalist for HVACR training
Microsoft One Note tutorial
Heat pump sequencer Heat sequencer
Brazing Settings
CH 81
FTC HVA 1171 Comm Ref and A/C
HVACR Duct Calculation
HVACR simulator
>
CENGAGE DELMAR HVAC Sim
Compressors
Brazing Lab
SURVEY
HVA1220 Mech Instrut Lab
>
TESTS
LABS
FTC HVA 1170 Domestic A/C Refrigeration
>
Quizzes
FINAL EXAM
ELE2053 Dig Electronics
>
Labs
Tests
PPTs
Refrigerants CHART
Homeworks
MITSUBISHI MR. SLIM
CBT College
Affidavit of Ackownoledge
EET1033 Fundamentals DC/AC
>
SYL
Homework
Cutler Bay Campus Calendar
FES1155 Fire Alarm Sys
>
Affidavit
HOMEWORKS
Syllabus
Study Guide
FASA Book
FX-64 Technical Manual
Programming Tutorial video linkew pageP
Tests
BCT1630 Residential Wiring
>
Syllabus
Affidavit
Grade Book
HOMEWORKS
EEV1230 Low Voltage Systems
>
AFFIDAVIT
ATTENDANCE
LABS
GRADEBOOK
HOMEWORKS
LABS
SYLLABUS
EEV1230 Tests
EEV1230 Final Study guide
EEV1230 Low Voltage Final Exam
DSC PC1616 PDF Manual
EET1051 EMC
>
HOMEWORKS
SYLLABUS
EET1051 Study Guide
NDS LOW VOLTAGE
Blog
JOURNEYMAN PREP
NDS EEV1230 LOW VOLTAGE
ATTENDANCE
EEV1230 ATT
608
BLENDER TUTORIAL
FTC ELE2101 NCCER L3M4 Term 4C
Javascript not enabled
Name:
ID:
Email:
FTC ELE2101 NCCER L3M4 Term 4C
Multiple Choice
Identify the choice that best completes the statement or answers the question.
A
B
C
D
1.
The space in the immediate vicinity inside of the motor dispensing unit at an automotive service station is identified as a
.
a.
Class III, Division 1 location
b.
Class II, Division 1 location
c.
Class I, Division 2 location
d.
Class I, Division 1 location
A
B
C
D
2.
A clothing manufacturing plant would most likely be classified as
.
a.
Class I, Division 1
b.
Class I, Division 2
c.
Class II, Division 1
d.
Class III
A
B
C
D
3.
Which of the following locations are hazardous due to the presence of combustible dust?
a.
Class I locations
b.
Class II locations
c.
Class III locations
d.
Class IV locations
A
B
C
D
4.
Common sources of ignition include electricity, sparking metal, heat-generating equipment, and failed
.
a.
electrical connections
b.
hydraulic connections
c.
pneumatic connections
d.
mechanical connections
A
B
C
D
5.
The main purpose of seals or sealoffs in conduit runs is to
.
a.
isolate different voltages from each other
b.
prevent the passage of gases, vapors, or flames from one portion of the system to another
c.
prevent moisture from entering the raceway system
d.
insulate the wires
A
B
C
D
6.
In hazardous locations where threaded metal conduit is required, threaded joints must be made up with at least how many threads fully engaged?
a.
2
b.
3
c.
4
d.
5
A
B
C
D
7.
Which of the following is approved for use in most Class I, Division 1 locations?
a.
Rigid metal conduit
b.
PVC
c.
Liquid-tight conduit
d.
EMT
A
B
C
D
8.
Which of the following best describes the devices that will help prevent moisture from collecting in raceway systems?
a.
Elbows
b.
Integral drains
c.
Strainers
d.
Sealoff fittings
A
B
C
D
9.
Locations in which flammable gases or vapors may be present in the air in quantities sufficient to produce explosive or ignitable mixtures are identified as
.
a.
Class I locations
b.
Class II locations
c.
Class III locations
d.
Class IV locations
A
B
C
D
10.
Anesthetizing locations of hospitals are considered to be Class I, Division 1 locations to a height of
.
a.
2' above the floor
b.
3' above the floor
c.
4' above the floor
d.
5' above the floor
Home
PLC FIDDLE PROJECTS
Personal Info
MY MEDIA FILES
FTC
FTC SM Projects Folder
PLC SIMULATOR
FTC ELE2101 NCCERL3M3 Term4C
FTC ELE2101 NCCERL3M4 Term4C
HVA1400 Midterm
NCCER Electrical HTML Tests
>
NCCER Elect L04M02
L04M10 Elect Motors Maintenance
L02M08 Conductor Terminations and Splices
L02M09 Grounding and Bonding
FTC Student contact list
Motor Calculation
CHILLERS MAG BEARINGS
My youtube channel
ATTENDANCE
EPA 608 TPC Study guide
>
ESCO Practice Manual 9ed 2018
EPA 608 Core Batch 1
HVACR House Load Calculation
CLICK PLC User Manual
NCCER useful links
PLC3000 07/29/19 ATTN sheet
Simulation links
Youtube plyalist for HVACR training
Microsoft One Note tutorial
Heat pump sequencer Heat sequencer
Brazing Settings
CH 81
FTC HVA 1171 Comm Ref and A/C
HVACR Duct Calculation
HVACR simulator
>
CENGAGE DELMAR HVAC Sim
Compressors
Brazing Lab
SURVEY
HVA1220 Mech Instrut Lab
>
TESTS
LABS
FTC HVA 1170 Domestic A/C Refrigeration
>
Quizzes
FINAL EXAM
ELE2053 Dig Electronics
>
Labs
Tests
PPTs
Refrigerants CHART
Homeworks
MITSUBISHI MR. SLIM
CBT College
Affidavit of Ackownoledge
EET1033 Fundamentals DC/AC
>
SYL
Homework
Cutler Bay Campus Calendar
FES1155 Fire Alarm Sys
>
Affidavit
HOMEWORKS
Syllabus
Study Guide
FASA Book
FX-64 Technical Manual
Programming Tutorial video linkew pageP
Tests
BCT1630 Residential Wiring
>
Syllabus
Affidavit
Grade Book
HOMEWORKS
EEV1230 Low Voltage Systems
>
AFFIDAVIT
ATTENDANCE
LABS
GRADEBOOK
HOMEWORKS
LABS
SYLLABUS
EEV1230 Tests
EEV1230 Final Study guide
EEV1230 Low Voltage Final Exam
DSC PC1616 PDF Manual
EET1051 EMC
>
HOMEWORKS
SYLLABUS
EET1051 Study Guide
NDS LOW VOLTAGE
Blog
JOURNEYMAN PREP
NDS EEV1230 LOW VOLTAGE
ATTENDANCE
EEV1230 ATT
608
BLENDER TUTORIAL